  • Vakuová měrka 901P

Vakuová měrka 901P

Pro více informací, prosím, kontaktujte prodejce:
  • Ing. Vojtěch Kroupa
  • +420 736 473 797
  • vojtech.kroupa@labtech.eu


Technická specifikace

Popis a vlastnosti vakuové měrky 901P

Vakuová měrka 901P používá pro měření senzory - MicroPirani™ (MEMS Thermal Conductivity) a Piezo differential (MEMS diaphragm).

Technická specifikace

01P
SensorMicroPirani™ (MEMS Thermal Conductivity)
Piezo differential (MEMS diaphragm)
Measuring Range
Absolute1.0 X 10-5 Torr to 1500 Torr
Differential-760 to +760 Torr
Set Point Range
Absolute5.0 X 10-4 Torr to 1000 Torr
Differential-760 to +100 Torr
Calibration GasAir, Argon, Helium, Nitrogen, H2, H2O vapor, CO2, Xenon, Neon
Operating Temperature Range0° to 40°C (32° to 104°F)
Maximum Bakeout Temperature85°C (185°F), non-operating
Digital CommunicationRS485/RS232 (4800 to 230400 Baud)
ControlsZero adjust, span adjust, analog output, pressure units, baud rate, address, factory default, set point functions: value, hysteresis, direction, enable, transducer status, switch, LED test
StatusAbsolute and differential pressure reading, units, set point, operating time, transducer temperature, user tag, model, device type, serial number, firmware and hardware versions, part number, manufacturer
Analog Output
Absolute Pressure1 to 9 VDC, 1 VDC/decade, 100Ω maximum output impedance
Resolution16 bit
Analog Output 2 (optional)
Piezo Differential5 VDC = 0 Torr, 1 VDC/decade
Resolution12 bit
Relays901P - 3 relays SPDT (optional)
Contact Rating1 A @ 30VAC/DC, resistive
Response100 msec maximum
Power Requirements9 to 30 VDC, < 1.2 watts max
Accuracy/Repeatability
MicroPirani™
  Accuracy5 X 10-4 to 1 X 10-3 Torr ±10% of reading
1 X 10-3 to 100 Torr ±5% of reading
100 Torr to Atm ±25% of reading
  Repeatability1 X 10-3 to 100 Torr ±2% of reading
Piezo Differential
  Accuracy-10 to +10 Torr ±10% of reading
-100 to -10 Torr ±8% of reading
-760 to -100 Torr ±1% of reading
+10 to 100 Torr ±5% of reading
  Repeatability-760 to +10 Torr ±1% of reading
  Zero Stability±0.1% of Full Scale (Full Scale = 760 Torr)
Overpressure Limit1500 Torr (Absolute)
Installation OrientationAny
Internal Volume(KF16) 2.8 cm3
Materials Exposed to VacuumSilicon, SiO2, Si3N4, gold, low outgassing epoxy resin, 304 stainless steel, Viton®
Electronic Casing and Flange304 stainless steel
Weight170 g (with KF 16 Flange)
ComplianceEMC Directive 2004/108/EC
Notes:Accuracy and repeatability are typical values measured with Nitrogen gas at ambient temperature after zero adjustment.
Máte dotaz?
Pole označená (*) musí být vyplněna
Email
Telefon
Váš Dotaz
Tučně označené položky je nutné vyplnit.

Naše nabídka
  • Baratron® - kapacitní manometry
  • MFC a MFM - Hmotnostní průtokoměry pro měření a řízení průtoku
  • HPS - vakuové měrky
    • řídící jednotky pro HPS snímače tlaku
    • vakuové měrky
  • Vakuové měrky a moduly - Granville Phillips
  • PLC - Programable Logic Controler

Vakuová měrka 902 B

Novinka, Vakuová měrka 902B
Více informací

Kontaktujte nás ještě dnesV případě, že jste na našich stránkách nenalezli odpověď na Vaše otázky, neváhejte nás kontaktovat.Kontaktujte nás

LABTECH s.r.o © 2011, Polní 23/340, CZ 639 00 Brno, Tel: +420 511 110 711, Fax: +420 543 210 115, info@labtech.eu
Webdesign : SHEAN